Victron Skylla-i Laddare

SKU
SKI0-24-VIC
Grouped product items
TuotenimiTuotenro Määrä
Skylla-i 24/100(1+1) 230V
Special Price €1602.48 Regular Price €1906.02
SKI024100000 In Stock (3-6 dagar)
Skylla-i 24/100(3) 230V
Special Price €1878.74 Regular Price €2233.96
SKI024100002 Out of Stock
Skylla-i 24/80(1+1) 230V
Special Price €1290.43 Regular Price €1576.76
SKI024080000 Out of Stock
Skylla-i 24/80(3) 230V
Special Price €1546.01 Regular Price €1839.56
SKI024080002 Out of Stock

En modern och kraftfull batteriladdare som tål påfrestningarna i svåra miljöer: hetta, fukt och salt atmosfär.
• Rätt laddning för bly-syrabatterier: variabel absorptionstid
• Batterisäkerhetsläge: förhindra skador till följd av för hög gasalstring
• Förvaringsläge: Mindre underhåll och åldrande när batteriet inte används
• Mindre och lättare än liknande modeller
• NMEA2000 Canbus-anslutning
• Effektkontroll: Ställ in max landspänning
• Fjärrkontroll
• Klar för Li-Ion (LiFePo4)
Modeller:24 Vol

Skylla-i (1+1): two outputs to charge 2 battery banks

The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery.

 

Skylla-i (3): three full current outputs to charge 3 battery banks

The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current.

 

Rugged

Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air.

Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.

 

Flexible

Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use.

Please refer to the manual for a complete overview of the possibilities.

 

Important features:

 

Synchronised parallel operation

Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details.

 

The right amount of charge for a lead-acid battery: variable absorption time

When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.

 

Preventing damage due to excessive gassing: the BatterySafe mode

If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.

 

Less maintenance and aging when the battery is not in use: the Storage mode

The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.

 

To increase battery life: temperature compensation

Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.

 

Battery voltage sense

In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage.

 

Suitable for AC and DC supply (AC-DC and DC-DC operation)

The chargers also accept a DC supply.

 

Use as a power supply

As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available.

 

Li-Ion (LiFePO4) ready

Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port.

 

Learn more about batteries and battery charging

To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free of charge from Victron Energy and downloadable from www.victronenergy.com).

 

Skylla-i

24/80 (1+1)

24/80 (3)

24/100 (1+1)

24/100 (3)

Input voltage (VAC)

230 V

Input voltage range (VAC)

185-265 V

Input voltage range (VDC)

180-350 V

Maximum AC input current @ 180 VAC

16 A

20 A

Frequency (Hz)

45-65 Hz

Power factor

0,98

Charge voltage 'absorption' (VDC) (1)

28,8 V

Charge voltage 'float' (VDC)

27,6 V

Charge voltage ‘storage’ (VDC)

26,4 V

Charge current (A) (2)

80 A

3 x 80 A

(max total output: 80A)

100 A

3 x 100 A

(max total output: 100A)

Charge current starter batt. (A)

4 A

n. a.

4

n. a.

Charge algorithm

7 stage adaptive

Battery capacity (Ah)

400-800 Ah

500-1000 Ah

Charge algorithm, Li-Ion

3 stage, with on-off control or CAN bus control

Temperature sensor

Yes

Can be used as power supply

Yes

Remote on-off port

Yes (can be connected to a Li-Ion BMS)

CAN bus communication port (VE.Can)

Two RJ45 connectors, NMEA2000 protocol, galvanically isolated

Synchronised parallel operation

Yes, with VE.Can

Alarm relay

DPST AC rating: 240VAC/4A DC rating: 4A up to 35VDC, 1A up to 60VDC

Forced cooling

Yes

Protection

Battery reverse polarity (fuse) Output short circuit Over temperature

Operating temp. range

-20 to 60°C (Full output current up to 40°C)

Humidity (non-condensing)

max 95%

ENCLOSURE

Material & Colour

aluminium (blue RAL 5012)

Battery-connection

M8 bolts

230 VAC-connection

screw-clamp 10mm² (AWG 7)

Protection category

IP 21

Weight kg (lbs)

7 kg (16 lbs)

Dimensions hxwxd in mm

(hxwxd in inches)

405 x 250 x 150 mm

(16.0 x 9.9 x 5.9 inch)

STANDARDS

Safety

EN 60335-1, EN 60335-2-29

Emission

EN 55014-1, EN 61000-6-3, EN 61000-3-2

Immunity

EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3

1) Output voltage range 20-36 V. 2) Up to 40°C (100°F) ambient.

Can be set with rotary switch or Output will reduce to 80% at 50°C, and to 60% at 60°C. potentiometers.